AccuThermo AW820RV Automatic RTP System

Home / Products / Rapid Thermal Process / AccuThermo AW820RV Automatic Vacuum RTP

AccuThermo AW820RV Automatic Vacuum RTP System

Allwin21 AccuThermo AW820RV Automatic Vacuum RTP System
ALLWIN21 ACCUTHERMO RTP PLATFORM

Automatic Vacuum RTP Configuration with Robotic Wafer Handling

Production-Oriented Automatic Vacuum RTP System for up to 8-Inch Wafers

Automatic Vacuum RTP Platform

Combines AW820R automatic wafer handling architecture with AW820V vacuum RTP chamber configuration for selected vacuum RTP applications.

Customer Gets:
Automatic single-wafer handling with vacuum process capability when the application truly requires vacuum RTP.

Top & Bottom Lamp Heating

Vacuum chamber configuration with top and bottom quartz windows, top and bottom lamp heating, and 10-zone lamp control.

Customer Gets:
More flexible thermal tuning for compound semiconductor, metal-film, and susceptor-based RTP applications.

Advanced RTP Control

RTAPRO software supports recipe factors, lamp-bank factors, lamp intensity limits, diagnostics, calibration, monitoring, and PowerSum process monitoring.

Customer Gets:
Better process setup, easier troubleshooting, and stronger process visibility for automatic vacuum RTP operation.

The AW820RV is an automatic vacuum RTP configuration for customers requiring robotic wafer handling together with vacuum pump-down, controlled pressure, or optional higher vacuum capability. It is intended for selected applications where vacuum RTP is justified by the process requirement, not simply by vacuum level alone.

CE Marked Equipment SEMI Member
CE Marked Equipment • SEMI Member Since 2007 • Atmospheric, Automatic, and Vacuum RTP Platform Configurations
Automatic Vacuum RTP or Atmospheric RTP?
1. Start with the Process Requirement

Vacuum RTP should be selected based on process requirements, not only by vacuum level. Many RTP applications can be processed using controlled atmospheric, nitrogen, argon, oxygen, or forming gas environments without requiring vacuum RTP configuration.

The AW820RV should be considered when the customer needs both automatic wafer handling and vacuum process capability.

Customer Gets:

  • More practical RTP model selection
  • Avoidance of unnecessary system complexity
  • Better matching between process requirement and equipment configuration
2. Automatic Wafer Handling with Vacuum Process Chamber

The AW820RV integrates robotic wafer handling with a vacuum RTP chamber. The configuration may include cassette station, robot transfer mechanism, wafer centering / cooling station, vacuum chamber interface, vacuum valves, pressure monitoring, and application-specific quartz tray or susceptor handling.

Customer Gets:

  • Reduced operator involvement
  • More repeatable wafer transfer sequence
  • Better fit for production-oriented vacuum RTP applications
3. Top & Bottom Lamp Heating

Unlike many conventional vacuum RTP systems using top-side-only heating, the AW820RV uses top and bottom lamp heating architecture. This configuration is useful for compound semiconductor, metal-film, and susceptor-based RTP applications.

Customer Gets:

  • More balanced thermal structure
  • Support for susceptor base and lid configurations
  • Improved flexibility for compound semiconductor processing
4. Shielded TC and Vacuum Pressure Control

Because the AW820RV uses a vacuum chamber structure with thick upper and lower quartz windows, shielded thermocouple temperature control is typically used instead of standard RTP pyrometer temperature control.

Vacuum pressure configuration, pump selection, pressure control method, process gases, susceptor configuration, wafer handling sequence, and cooling strategy should be reviewed together before final configuration.

Customer Gets:

  • Temperature control compatible with vacuum chamber structure
  • Application-oriented vacuum RTP configuration
  • More realistic review of process capability and throughput
RTP Process Knowledge
Process Results vs. Temperature Uniformity

For RTP applications, direct TC temperature uniformity alone may not represent final process performance. Sheet resistance, film thickness, contact resistance, SEM results, and repeatability often provide more meaningful process evaluation.

Customer Gets:

  • Better acceptance criteria
  • Less confusion during process development
  • More practical RTP evaluation
Atmospheric RTP vs. Vacuum RTP

Many RTP applications do not require vacuum RTP. For many processes, thermal repeatability, gas purity, O₂ / moisture control, chamber design, and process understanding are more important than vacuum level alone. Vacuum RTP systems may also introduce additional contamination sources, increased maintenance complexity, and reduced process repeatability at high temperatures due to chamber structure and cooling requirements.

Customer Gets:

  • Avoid unnecessary complexity
  • Better model selection
  • Practical RTP configuration guidance
Cooling Water Stability

Closed-loop cooling water is recommended for stable RTP chamber cooling and long-term reliability. Because RTP is a high-temperature thermal processing system, a dedicated cooling-water loop is recommended whenever possible. Distilled water is recommended instead of D.I. water for chamber cooling.

Customer Gets:

  • Reduced corrosion risk
  • More stable chamber behavior
  • Better long-term equipment reliability
Susceptor Selection

The appropriate susceptor depends on budget, substrate size, material, thickness, emissivity, wafer bow, backside surface condition, ramp-rate requirements, patterned surface condition, process temperature, throughput, and application requirements. Susceptor size and configuration can also affect achievable ramp rates, thermal repeatability, and process flexibility. Susceptor base or susceptor base + lid configurations may be recommended depending on process sensitivity and wafer surface conditions.

Customer Gets:

  • Better process and budget matching
  • Reduced wafer handling risk
  • Improved thermal repeatability potential
  • More suitable RTP configuration for application-specific process needs
Quick Specifications
Item AW820RV Specification
Ramp-Up Rate Programmable from 1°C to 250°C/sec.

 

More details
Typical compound semiconductor applications use 1°C to 50°C/sec depending on process, substrate size, substrate material, vacuum pressure, automatic handling configuration, and susceptor configuration.
Steady-State Temperature Typical steady-state range: 150°C to 1150°C.

 

More details
Maximum temperature up to 1250°C depending on process conditions, wafer size, susceptor configuration, process gas, vacuum pressure, and system configuration. Long-duration high-temperature processing should be reviewed with Allwin21 before application use, since process safety, chamber condition, utility stability, exhaust configuration, vacuum pump configuration, and facility capability become increasingly important for long-duration RTP operation.
Steady-State Duration 0 to 9999 seconds per recipe step.

 

More details
Typical RTP applications use approximately 1 to 600 seconds per recipe step. Actual process duration depends on process temperature, substrate type, process gas, vacuum pressure, recipe requirements, pump-down / purge sequence, wafer handling sequence, and cooling requirements.
Ramp-Down Rate 1°C to 200°C/sec. Programmable within natural cooling capability.

 

More details
Actual cooling rate is temperature- and substrate-dependent. Cooling can be fast at high temperature and gradually decreases at lower temperature, especially below approximately 200°C. For higher-throughput automatic RTP applications, selected hot-wafer handling or external cooling-station strategies may be reviewed depending on vacuum sequence, wafer type, and safety requirements.
Temperature Accuracy Thermocouple measurement resolution / accuracy: ±1°C under controlled conditions.
Temperature Repeatability ±1°C or better at 1150°C under controlled conditions.

 

More details
Based on wafer-to-wafer repeatability test under controlled process conditions. Actual repeatability depends on substrate, fixture, sensor configuration, vacuum pressure, process recipe, pump-down sequence, and facility stability.
Temperature Uniformity ±8°C across an 8″ / 200 mm wafer at 1150°C.

 

More details
Based on one-sigma deviation from 100 Å oxide uniformity measurements. RTP performance is application dependent and should be confirmed by final process requirements and acceptance criteria.
Allwin21 generally recommends using final process results such as sheet resistance, film thickness, contact resistance, device performance, surface condition, or SEM results as meaningful process acceptance criteria.
Process / Purge Gases Supports common RTP process and purge gases.

 

More details
Typical gases include N₂, O₂, Ar, He, forming gas, NH₃, and N₂O. Process gases should be regulated to 30 PSIG and pre-filtered to 1 micron. Final gas configuration depends on pressure control method, vacuum pump compatibility, process chemistry, and customer facility standards.
Vacuum / Pressure Configuration Typical low-vacuum configuration approximately 1 to 50 mTorr. Optional high-vacuum configuration may be reviewed for selected applications.

 

More details
Typical low-vacuum RTP configurations are commonly operated approximately in the 1 to 30 mTorr or 1 to 50 mTorr range depending on pump configuration, chamber condition, process gas, pressure-control method, leak rate, and customer application requirements.
Optional turbo-pump configuration may be reviewed for applications requiring higher vacuum capability. Typical high-vacuum configurations may reach approximately 10⁻⁵ to 10⁻⁷ Torr depending on chamber condition, pump configuration, plumbing, valve configuration, leak rate, process gas configuration, and facility setup.
Actual achievable vacuum performance and process suitability are application dependent and should be reviewed together with substrate material, process gas, temperature, susceptor configuration, process sequence, and customer evaluation method.
Typical Throughput Application dependent; automatic vacuum RTP throughput is normally lower than atmospheric automatic RTP.

 

More details
Actual throughput depends on wafer size, process temperature, process duration, pump-down time, purge / backfill sequence, cooling requirements, wafer handling configuration, susceptor configuration, and vacuum level requirement. Automatic vacuum RTP should be reviewed based on the customer’s real production target and process sequence.
Standard & Optional Configuration
Item AW820RV Standard Configuration
System Type Automatic single-wafer vacuum RTP / RTA / RTO / RTN system for selected production-oriented vacuum RTP applications.
Wafer Handling System Automatic cassette-based robotic wafer transfer into the vacuum RTP process chamber.

 

More details
The AW820RV uses an integrated robotic wafer handling architecture adapted for vacuum RTP operation. The standard automation configuration may include cassette station, wafer centering / cooling station, robot transfer mechanism, vacuum chamber transfer interface, application-specific quartz tray or susceptor handling configuration, and automatic process sequence control. Final wafer handling configuration depends on wafer size, thickness, bow, substrate material, susceptor selection, vacuum process sequence, process temperature, cooling requirement, and throughput target.
Wafer Size Capability Supports selected round and square substrates up to 8-inch class, configuration dependent.

 

More details
Supports selected small samples, 2”, 3”, 4”, 5”, 6″, and 8” / 200 mm wafer configurations depending on cassette, robot end-effector, quartz tray, susceptor, automation configuration, substrate thickness, wafer bow condition, and application requirements. Final wafer size support must be confirmed before order placement.
Vacuum Metal Chamber Assembly AW820RV automatic vacuum RTP chamber with top and bottom quartz windows, 27 lamps, and 10-zone control.

 

More details
Includes vacuum chamber structure, top and bottom quartz windows, top and bottom infrared lamp heating module, independent lamp-bank control with recipe-level lamp factor adjustment, vacuum pressure interface, and automatic wafer transfer interface. The vacuum chamber structure is different from the standard atmospheric isolated quartz tube structure.
Chassis Assembly Automated AW820RV RTP chassis with embedded industrial computer, automation control, and vacuum control architecture.

 

More details
Includes automated RTP main frame, embedded industrial control computer for reduced ESD risk, integrated robotic wafer handling control architecture, cassette station, wafer centering / cooling station, touchscreen monitor, EMO, exhaust cooling fans, main control electronics, AC/DC power supplies, vacuum control interface, vacuum pressure control valve, main vacuum valve, vacuum gauges / meters, N₂ purge line, process gas lines with MFCs, cooling water and CDA gauges, meters, valves, and switches. Additional production-oriented safety and monitoring features may include smoke detect sensor, water leak sensors, input and return cooling-water pressure meters, bypass cooling-water line, and application-dependent system monitoring configurations.
Standard Quartz Trays Standard quartz trays available for selected round and square substrates.

 

More details
Standard quartz tray configurations may be reviewed for selected round wafers and square substrates depending on automation configuration and wafer handling requirements. Final quartz tray configuration depends on substrate size, shape, thickness, wafer bow condition, process temperature, vacuum sequence, automation configuration, robot end-effector configuration, susceptor selection, and application-specific wafer handling requirements.
Thermocouple One shielded K-type thermocouple assembly included.

 

More details
AW820RV vacuum RTP typically uses shielded thermocouple measurement because of the vacuum chamber and quartz window structure. Pyrometer temperature control is generally not recommended for this vacuum chamber configuration. Typical process range is approximately 150°C to 1100°C depending on process conditions, mounting configuration, and application requirements.
Manuals & Software USB drive with manuals, software, and schematics included.

 

More details
Includes backup software, installation manual, operation manual, service manual, facility connection drawings, and AW820RV schematics.
Item Optional Configuration / Capability
More Process Gas Lines Optional additional process gas lines with support for up to 5 MFCs.

 

More details
AW820RV includes a dedicated N₂ purge line for vacuum chamber purge / backfill use. Additional process gas lines are available with optional shut-off valves, gas routing configurations, pressure control interface, and up to 5 MFCs depending on application-specific gas requirements.
Special Wafer Handling Optional fragile-wafer, thin-wafer, susceptor-based, and hot-wafer handling configurations.

 

More details
Special robot end-effector configurations are available for fragile substrates and compound semiconductor applications. Final handling capability depends on wafer size, wafer bow condition, substrate material, process temperature, vacuum sequence, cooling requirement, robot end-effector configuration, and application-specific process conditions.
Application-Specific Susceptors Application-specific graphite susceptors available for selected AW820RV RTP applications.

 

More details
AW820RV is an automatic single-wafer vacuum RTP system. Susceptor configuration selection depends on substrate material, transparency to IR heating, wafer backside condition, patterned or metal-coated surface condition, process sensitivity, repeatability requirements, ramp-rate requirements, vacuum pressure, and throughput goals.
Susceptor base-only or susceptor base + lid configurations are available depending on application requirements. For many compound semiconductor and vacuum RTP applications, susceptor base + lid configurations may be reviewed for improved thermal repeatability, wafer-to-wafer consistency, and process uniformity.
Standard long-term qualified graphite susceptors with SiC coating are recommended for best RTP repeatability, stability, and long-term reliability. Allwin21 generally does not recommend unqualified alternative susceptor materials because long-term supply stability, contamination risk, coating quality, and repeatability performance may vary significantly depending on vendor and material quality.
Application-Specific Quartz Trays Standard and/or custom quartz tray / handling configurations available for special substrates.

 

More details
Custom quartz tray and handling configurations are available for special wafer configurations, thin wafers, fragile substrates, bowed wafers, non-standard substrate formats, and application-specific process requirements after engineering review.
Vacuum Pump / Pressure Configuration Mechanical pump, dry pump, turbo pump, and pressure control interface can be reviewed.

 

More details
Allwin21 strongly recommends that customers select and purchase vacuum pumps based on their existing fab or laboratory pump standards whenever possible. Many fabs and laboratories prefer to standardize pump suppliers, pump models, spare parts, fittings, maintenance procedures, and support infrastructure across multiple equipment platforms for easier long-term maintenance and facility support.
Using different pump suppliers or pump models for different equipment may increase future maintenance complexity, spare-parts management burden, support difficulty, and long-term operating cost.
After receiving the RTP equipment purchase order, Allwin21 can provide the corresponding facility and vacuum pump requirement information, including recommended pumping capability, pressure range, cooling requirements, exhaust requirements, and interface recommendations.
Allwin21 can also recommend suitable pump and chiller models if requested. If the customer requires bundled purchasing for project, grant, or funding reasons, Allwin21 can review pump or chiller supply case by case.
Cooling Water Monitoring Optional individual water-flow monitoring for each cooling-water circuit available.
Support & Service Optional spare parts, installation, training, and process support.

 

More details
Worldwide engineering support, startup assistance, RTP training, process discussion, remote support, and field service are available depending on customer requirements.
GEM/SECS Interface Optional GEM/SECS factory communication interface.

 

More details
Supports communication with factory automation systems and fab host / MES integration when required.
SMIF Wafer Loader Port Optional SMIF wafer loader port for automated wafer handling integration.

 

More details
Supports integration with selected SMIF wafer loading systems for automated wafer transfer and factory automation applications. Allwin21 can supply selected SMIF wafer loader configurations, or customer-specified standard SMIF systems may be integrated depending on customer fab standards and configuration requirements.
High Vacuum Capability Optional turbo pump configuration for higher vacuum requirement.

 

More details
Optional turbo pump configuration may be reviewed for customers requiring higher vacuum capability. Actual vacuum performance depends on pump selection, chamber condition, plumbing, valve configuration, leak rate, and facility setup.
Typical Applications
Automatic Vacuum RTPRTARTORTNOhmic AlloyingImplant ActivationSilicide AnnealingGaAsInPGaNSiCIII-V / II-VI MaterialsMetal-Film AnnealingO₂-Sensitive ProcessesProduction Fab RTPFab Automation Integration
Facility Requirements
Facility Item Typical Requirement
Electrical Approx. 100 Amps
208–240 VAC, 60 Hz, 3-phase, 4-wire — North America typical
200 VAC, 50/60 Hz, 3-phase — Japan typical
380–415 VAC, 50 Hz, 3-phase, 5-wire — Europe / China typical

 

Please confirm facility power configuration before order placement.

Cooling Water Closed-loop cooling water recommended
Typical flow: 3–5 GPM
Typical pressure: 30–40 PSI
Recommended temperature: approximately 20°C
Typical fitting: 1/2″ tubing
Recommended chiller: SMC HRSF060-AN-20 or equivalent industrial closed-loop recirculating chiller
Quartz Window / Chamber Cooling Gas / CDA N₂ or CDA
Oil-free and water-free gas recommended
Typical pressure: 15–30 PSI
Typical flow: 10–15 SCFM
Typical fitting: 3/8″ tubing
Process Gases / Exhaust N₂ / O₂ / Ar / He / Forming Gas / NH₃
Typical process gas pressure: 10–30 PSI
Typical fitting: 1/4″ VCR
4-inch exhaust duct recommended
Vacuum Pump / Exhaust Vacuum pump and pump exhaust requirements depend on selected pump configuration, vacuum level, process gas, and customer facility standard. Customer pump standard should be reviewed before final configuration.
Closed-loop recirculating cooling water system is strongly recommended. Distilled water or suitable coolant is recommended for the chiller system. Do NOT connect facility DI water directly to the RTP chamber cooling lines. For best RTP stability and chamber lifetime, Allwin21 recommends using a dedicated cooling loop and not sharing the cooling system with other fab or laboratory equipment. Final facility requirements depend on RTP configuration, process application, and local facility standards.
The facility requirements listed above are for the AW820RV RTP system only and do not include the electrical power, cooling water, exhaust, or utility requirements for mechanical pump, dry pump, turbo pump, or other customer-selected vacuum pump packages. Vacuum pump requirements depend on the pump model, supplier, vacuum level, and customer facility standard. Customer is responsible for facility and pump or chiller if applicable.
Dimensions and Weight
Item Information
AW820RV Equipment Dimensions Approx. 39″ W × 54″ D × 70″ H, configuration dependent
AW820RV Net Weight Approximately 800 lbs, configuration dependent
Shipping Crate Dimensions Approx. 48″ W × 62″ D × 81″ H, configuration dependent
Shipping Weight Approximately 1455 lbs, configuration dependent
RTP RFQ / Requirement Survey

Please provide as much information as possible in the RTP Survey PDF and email the completed survey to sales@allwin21.com and/or allwin21corp@gmail.com.

The more complete and accurate your responses are, the better we can recommend the most suitable RTP model or configuration for your specific needs, based on our 45+ years of RTP technology heritage and more than 1,500 RTP systems worldwide.

Completing the survey thoroughly helps ensure optimal system performance while avoiding unnecessary options that do not contribute to your application.

Download RTP Requirement Survey PDF

Important Notes
  • Product photos and descriptions are for general reference only.
  • Final configuration, options, specifications, facility requirements, lead time, and delivery schedule shall be confirmed by Allwin21 official quotation and technical documents.
  • Facility requirements depend on actual system configuration, process gases, vacuum pump configuration, pressure control configuration, automation configuration, and customer process requirements.
  • Vacuum pump, chiller, exhaust, facility hook-up, and local code compliance are normally customer responsibility unless specifically included in the official quotation.
  • OEM trademarks belong to their respective owners.